The following is the complete list of parameters and features available in the fully licensed version.
Parameter Index
Parameters
The message that are displayed in the applet. The different messages must be separated with a | .
Typical Value: "Welcome To Our Web Site|Click Here To Enter"
Range Of Values: There is no limit, have as many messages as you want.
Default Value: "No messages have been put in the parameters"
A url where the viewer is taken when they click on the applet. If this parameter is not specified then the applet will not link to another web site.
Typical Value: "http://www.jpowered.com"
Range Of Values: Any Text
Default Value: " "
This sound is played every time a letter is displayed. It must be an AU file(.au file extension). You can have a unique value for each message, all you have to do is separate each value with a | e.g. "value1|value2". Each value will correspond to the reflecting message in the Text parameter.
Typical Value: "type.au"
Range Of Values: .au file name
Default Value: "none"
Defines the background color of the applet.
Typical Value: "0,0,0"
Range Of Values: "0-255,0-255,0-255"
Default Value: "255,255,255"
Defines the text color. You can have a unique value for each message, all you have to do is separate each value with a | e.g. "value1|value2". Each value will correspond to the reflecting message in the Text parameter.
Typical Value: "255,255,255"
Range Of Values: "0-255,0-255,0-255"
Default Value: "0,0,0"
Defines the font of the text. You can have a unique value for each message, all you have to do is separate each value with a | e.g. "value1|value2". Each value will correspond to the reflecting message in the Text parameter.
Typical Value: "TimesRoman"
Range Of Values: "Dialog" - "SansSerif" - "Serif" - "Monospaced" - "Helvetica" - "TimesRoman" - "Courier" - "DialogInput" - "ZapfDingbats"
Default Value: "Helvetica"
A number which defines the font size. You can have a unique value for each message, all you have to do is separate each value with a | e.g. "value1|value2". Each value will correspond to the reflecting message in the Text parameter.
Typical Value: "22"
Range Of Values: "8" - "200"
Default Value: "12"
Specifies if the font is bold or not. You can have a unique value for each message, all you have to do is separate each value with a | e.g. "value1|value2". Each value will correspond to the reflecting message in the Text parameter.
Typical Value: "Yes"
Range Of Values: "Yes" - "No"
Default Value: "No"
Specifies if the font is italic or not. You can have a unique value for each message, all you have to do is separate each value with a | e.g. "value1|value2". Each value will correspond to the reflecting message in the Text parameter.
Typical Value: "Yes"
Range Of Values: "Yes" - "No"
Default Value: "No"
Specifies if the text should be aligned to the left, centre or right. You can have a unique value for each message, all you have to do is separate each value with a | e.g. "value1|value2". Each value will correspond to the reflecting message in the Text parameter.
Typical Value: "Centre"
Range Of Values: "Left" - "Centre" - "Right"
Default Value: "Left"
Defines what happens to the text after it has been typed. You can have a unique value for each message, all you have to do is separate each value with a | e.g. "value1|value2". Each value will correspond to the reflecting message in the Text parameter.
Typical Value: "FadeOut"
Range Of Values: "FadeOut" - "ScrollUp" - "Shrink" - "NoEffect"
Default Value: "NoEffect"
Defines how fast the after effect is carried out. The lower this number the faster it is. You can have a unique value for each message, all you have to do is separate each value with a | e.g. "value1|value2". Each value will correspond to the reflecting message in the Text parameter.
Typical Value: "20"
Range Of Values: "0" - "1000"
Default Value: "30"
Defines how fast the text is typed. The lower this number then the faster the text is typed. You can have a unique value for each message, all you have to do is separate each value with a | e.g. "value1|value2". Each value will correspond to the reflecting message in the Text parameter.
Typical Value: "100"
Range Of Values: "0" - "1000"
Default Value: "60"
Defines how long in milliseconds to display the text after it has been typed before it disappears. You can have a unique value for each message, all you have to do is separate each value with a | e.g. "value1|value2". Each value will correspond to the reflecting message in the Text parameter.
Typical Value: "4000"
Range Of Values: "0" - "100000"
Default Value: "2000"
Defines how long in milliseconds after the text has disappeared before typing the next line of text. You can have a unique value for each message, all you have to do is separate each value with a | e.g. "value1|value2". Each value will correspond to the reflecting message in the Text parameter.
Typical Value: "2000"
Range Of Values: "0" - "100000"
Default Value: "0"
You can decide is you want the applet to repeat it's sequence of messages or stop after the first sequence.
Typical Value: "No"
Range Of Values: "Yes" - "No"
Default Value: "Yes"
If you specify no on the Repeat parameter then you can decide if you want the applet to jump to it's hyperlink (Link parameter).
Typical Value: "Yes"
Range Of Values: "Yes" - "No"
Default Value: "No"
![]()
© 2000 JPowered.com.